Gulf Harmony HVI Plus 100
Supreme quality high viscosity index hydraulic oil for extreme temperature ranges
Features & Benefits
- Outstanding thermo-oxidative stability reduces deposit formation, improves pump performance and gives extended oil and filter change intervals
- Extremely high viscosity index assures equipment protection at cold start-up temperatures as well as at high operating temperatures
- Exceptional anti-wear property results in fewer breakdowns, longer pump life and reduced maintenance costs
- Excellent demulsibility helps in faster separation of water from oil and resists formation of emulsions
- Special rust & corrosion inhibitors protect multi-metallurgy components against negative effects of moisture presence in the system
- Rapid air release property minimises chances of pump cavitation and thus prevents component damage, reduces vibration and maintains efficiency especially in modern hydraulic systems where sump sizes are becoming smaller
- Offers long term hydrolytic stability and yellow metal compatibility in presence of water
- Compatible with multi-metals & most sealing materials used in hydraulic systems
Applications
- Hydraulic and power transmission systems subjected to a wide range of ambient & operating temperatures
- Applications requiring extended oil change intervals
- Critical hydraulic systems such as high accuracy numerically controlled machine tools and those employing close clearance servo valves
- Hydraulic systems of excavators, cranes and hydrostatic drives subjected to most severe outdoor operating conditions
- Hydraulic systems operating under high pressures and requiring high degree of load carrying capability and anti-wear protection
Specifications, Approvals & Typical Properties
|
ISO Viscosity grades |
15 |
22 |
32 |
46 |
68 |
100 |
150 |
||
|
Meets the following Specifications |
|
|
|||||||
|
DIN 51524 Part 3 HVLP |
x |
x |
x |
x |
x |
x |
x |
||
|
AFNOR NFE 48-603 (HV) |
|
|
x |
x |
x |
x |
|
||
|
ISO 11158 HV |
x |
x |
x |
x |
x |
x |
x |
||
|
Denison HF-0, HF-1, HF-2 |
x |
x |
x |
x |
x |
|
|
||
|
Eaton (Vickers) M-2950-S, M-2952-S, I-286-S |
x |
x |
x |
x |
x |
|
|
||
|
Bosch Rexroth 07 075 for vane, piston & gear pumps, Sauer Danfoss 520L0463 |
|
|
x |
x |
x |
|
|
||
|
Poclain |
|
|
|
|
x |
x |
|
||
|
Hitachi |
|
|
|
x |
|
|
|
||
|
Has the following Approvals |
|
|
|||||||
|
FIVES CINCINNATI (Former MAG IAS, LLC) |
|
|
P-68 |
P-70 |
P-69 |
|
|
||
|
Typical Properties |
|
|
|||||||
|
Test Parameters |
ASTM |
Test Values |
|
|
|||||
|
Viscosity @ 40 C, cSt |
D 445 |
14.9 |
22.5 |
32.2 |
46.9 |
68.9 |
99.3 |
147.2 |
|
|
Viscosity Index |
D 2270 |
152 |
151 |
152 |
151 |
152 |
152 |
152 |
|
|
Flash Point, C |
D 92 |
180 |
192 |
219 |
222 |
232 |
242 |
248 |
|
|
Pour Point, C |
D 97 |
-42 |
-42 |
-39 |
-36 |
-36 |
-33 |
-30 |
|
|
Density @ 15C, Kg/l |
D 1298 |
0.855 |
0.857 |
0.861 |
0.855 |
0.858 |
0.861 |
0.862 |
|
|
Rust Test |
D 665A/B |
Pass |
Pass |
Pass |
Pass |
Pass |
Pass |
Pass |
|
|
Emulsion Test 30 minutes max |
@ 54 oC |
D 1401 |
Pass |
Pass |
Pass |
Pass |
Pass |
- |
- |
|
@ 82 oC |
- |
- |
- |
- |
- |
Pass |
Pass |
||
|
Foam Test, foam after 10 minutes of settling for all sequences |
D 892 |
Nil |
Nil |
Nil |
Nil |
Nil |
Nil |
Nil |
|
|
Turbine Oil Stability Test, hrs |
D 943 |
5000+ |
|
4000+ |
|||||
|
FZG, fail load stage, minimum |
DIN 51354 Part II |
- |
- |
11 |
11 |
11 |
11 |
11 |
|